Product name:MC1-D AC Contactors

MC1-D AC Contactors

 

MC1-D-09/12

MC1-D-18

MC1-D-25

Environment

Type

 

MC1-D
09...18
T20&T25

MC1-D
25...38
T32&T40

MC1-D
40

MC1-D
50...95

MC1-D115&MC1-D150

Rated insulation voltage (Ui)

Conforming to IEC 947-4-1,overvoltage category III,degree of pollution:3

690V

690V

690V

690V

690V

Rated impulse withstand voltage(Uimp)

Conforming to IEC947

6kV

6kV

8kV

8kV

8kV

Conforming to standards

 

IEC947-1,947-4-1,EN 60947-1,60947-4-1

Degree of protection(1)

Power connection

Protection against direct finger contact IP2X

Front face only

Coil connection

Protection against direct finger contact IP 2X(except MC1-D40...80

Protective treatment

Conforming to IEC68

"TH"

Ambient air temperature

Storage

-60...+80 ?

Around the device

Operation

-5...+60?

 

Permissible

-40...+70?,for operation at Uc

Maximum operating altitude

Without derating

3000m

Operating position

Without derating

±30°possible, in relation to normal vertical mounting plane

Flame resistance

Conforming to IEC 695-2-1

960?

Shock resistance(2)

Contactor open

10gn

8gn

8gn

8gn

6gn

1/2 sine wave=11HM

Contactor closed

15gn

15gn

10gn

10gn

15gn

Vibration resistance(2)

Contactor open

2gn

2gn

2gn

2gn

2gn

5...300Hz

Contactor closed

4gn

4gn

4gn

3gn

4gn

 

(1), Protection ensured for the connection cross-sections shown on the nex t page and for connection via cable
(2), In the least favourable direction,without change of contact state(coil supplied at Ue)

Power circuit connections-Connection via cable

Type

MC1-D

09&12
T20&T25

18(3P)

25

32&38

18&25(4P) T32&T10

40

50&65

80&95

115&150

Tightening

 

Screw clamps

2-input cnnector

Screw clamps

1-input connector

2-input connector

Flexible cable without cable end (mm2)

1 conductor

1...4

1.5...6

1.5...10

2.5...10

2.5...10

2.5...25

2.5...25

4...50

10...120

2 conductor

1..4

1.5...6

1.5...6

2.5...10

2.5...10

2.5...16

2.5...16

4...25

10...120+10...50

Fiexible cable with cable end (mm2)

1 conductor

1...4

1...6

1...6

1...10

2.5...10

2.5...25

2.5...25

4...50

10...120

2 conductor

1...2.5

1...4

1...4

1.5...6

2.5...10

2.5...10

2.5...10

4...16

10...120+10...50

Solid cable without cable end (mm2)

1 conductor

1...4

1.5...6

1.5...6

1.5...10

2.5...16

2.5...25

2.5...25

4...50

10...120

2 conductor

1...4

1.5...6

15....6

2.5...10

2.5...16

2.5...16

2.5...16

4...25

10...120+10...50

Screwdriver

Head

N°2

N°2

N°2

N°2

N°2

--

--

--

--

? flat screwdrive

?6

?6

?6

?6

?6

?6...?8

?6...?8

?6...?8

--

6 sided key

--

--

--

--

--

--

--

4

4

Tightenning torque (N.m)

1.7

1.7

2.5

2.5

1.8

5

 

9

12

Connection via spring terminals(2)

Flexibl cable without cable end (mm2)

1 conductor

2.5(4:T25)

4

4

4

--

10

--

--

 

2 conductor

2.5(except T25:-)

4

4

4

--

--

---

--

 

Connection via bars or lugs

Bar cross-section

--

--

--

--

--

--

--

--

--

Lug external ?

8

8

10

10

8(1)

13

16

17

25

? of screw

M3.5

M3.5

M4

M4

M3.5

M5

M6

M6

M8

Screwdriver

Head

N°2

N°2

N°2

N°2

N°2

N°2

N°2

--

--

?flat screwdriver

?6

?6

?6

?6

?6

?8

?8

?8

--

Key for hexagonal headed screw

--

--

--

--

--

--

--

10

13

Tightening torque

1.7

1.7

2.5

2.5

1.8

5

5

9

12

Power circuit connections-Connection via cable(tightening via screw clamps)

Type

MC1-D

09&12
T20&T25

18(3P)

25

32&38

18&25(4P) T32&T10

40

50&65

80&95

115&150

Flexible cable without cable end (mm2)

1 conductor

1...4

1..4

1...4

1...4

1...4

1...4

1...4

1...4

1...2.5

2 conductor

1...4

1...4

1...4

1...4

1...4

1...4

1...4

1...4

1...2.5

Fiexible cable with cable end (mm2)

1 conductor

1...4

1...4

1...4

1...4

1...4

1...2.5

1...2.5

1...2.5

1...2.5

2 conductor

1..2.5

1...2.5

1...2.5

1...2.5

1...2.5

1...2.5

1...2.5

1...2.5

1...2.5

Solid cable without cable end (mm2)

1 conductor

1...4

1...4

1...4

1...4

1...4

1...4

1...4

1...4

1...2.5

2 conductor

1...4

1...4

1...4

1...4

1...4

1...4

1...4

1...4

1...2.5

Screwdriver

Head

N°2

N°2

N°2

N°2

N°2

N°2

N°2

N°2

N°2

? flat screwdrive

?6

?6

?6

?6

?6

?6

?6

?6

?6

Tightenning torque (N.m)

1.7

1.7

1.7

1.7

1.7

1.2

1.2

1.2

1.2

Connection via spring terminals(2)

Flexibl cable without cable end (mm2)

1 conductor

2.5

2.5

2.5

2.5 --

2.5

--

--

--

--

2 conductor

2.5

2.5

2.5

2.5 --

2.5

--

---

--

--

Connection via bars or lugs

Lug external ? (mm)

8

8

10

10

8

13

16

17

25

? of screw (mm)

M3.5

M3.5

M3.5

M3.5

M3.5

M3.5

M3.5

M3.5

M3.5

Screwdriver

Head

N°2

N°2

N°2

N°2

N°2

N°2

N°2

N°2

N°2

?flat screwdriver

?6

?6

?6

?6

?6

?6

?6

?6

?6

Tightening torque (N.m)

1.7

1.7

1.7

1.7

1.7

1.2

1.2

1.2

1.2

(1) To connect cables with a c.s.a.>4mm2 and up to 10mm2 ,it is essential to use spectial connectors ,sold in bags lf 100 (reference:MC1-D-961860)
(2) If cable ends are used, choose the next size down (example: for 2.5 mm2,use 1.5mm2 )and square crimp the cable ends using a special tool

 

MC1-D-32

MC1-D-40/50/65

MC1-D-80/95

Pole characteristics

Type

MC1-D-

09
(3P)

T20
&098

12
(3P)

T25&125

18(3P)

T32&188

25(3P)

T40&258

32

38

Rated operational current(le)
(Ue=440V) ( A)

In AC-3,?=60?

9

9

12

12

18

18

25

25

32

38

In AC-1,?=60?

25(1)

20

25(1)

25

32(1)

32

40(1)

40

50(1)

50

Rated operational voltage(Ue) ( V )

Up to

690

690

690

690

690

690

Frequency limits ( Hz)

Of the operating current

25...400

25...400

25...400

25...400

25...400

25...400

Conventional thermal current(lth)

?=60?

25(1)

20

25(1)

25

32(1)

32

40(1)

40

50

50

Rated making capacity(440V)

Conforming to IEC 947

250

250

300

450

550

550

Rated breaking capacity(440V)

Conforming to IEC 947

250

250

300

450

550

550

Permissible short-time rating
No current flowing for preceding
15 minutes at ? =40?

For 1 s

210

210

240

380

430

430

For 10 s

105

105

145

240

260

310

For 1min

61

61

84

120

138

150

For 10 min

30

30

40

50

60

60

Protection by fuse against
short-circuits(U=690V)

Without thermal type 1

25

40

50

63

63

63

Overload relay,fuse gG type 1

20

25

35

40

63

63

With thermal overload relay

See pages 24514/2 and 24514/3, for aM or gG fuse ratings corresponding to the associated thermal overload relay

Average impedance per pole (WO)

At lth and 50Hz

2.5

2.5

2.5

2

2

2

Power dissipation per pole for

AC-3(W)

0.20

0.36

0.8

1.25

2

3

The above operating currents

AC-1 (W)

1.56

1.56

2.5

3.2

5

5

a.c. control circuit characteristics

Rated control circuit voltage(Uc)

50/60Hz

V

12...690

Control voltage limits

50 or 60 Hz coils

Operational

 

-

50/60 Hz coils

Drop-out

 

-

 

Operational

VA

0.8...1.1 Uc on 50 Hz and 0.85...1.1 Uc on 60 Hz at 60?

Drop-out

 

0.3...0.6 Uc at 60 ?

Average consumption
at 20? and at Uc

~50Hz

Inrush

50 Hz coil

VA

-

Cosf

 

0.75

50/60 Hz coil

VA

70

Sealed

50 Hz coil

VA

-

Cosf

 

0.3

50/60 Hz coil

VA

7

~60Hz

Inrush

50 Hz coil

VA

-

Cosf

 

0.75

50/60 Hz coil

VA

70

Sealed

 

VA

-

Cosf

 

0.3

50/60 Hz coil

VA

7.5

Heat dissipation 50/60 Hz

 

W

2...3

Operating time(2)

Closing "C"

ms

12...22

Opening "O"

ms

4...19

Mechanical life
in millions of operating cycles

50 or 60 Hz coil

 

-

50/60 Hz coil on 50 Hz

 

15

Maximum operating rate
at ambient temperature =60?

In operating cycles per hour

 

3600

 

(1) Versions with spring terminal connections:20A for MC1-D-093 and MC1-D-123,25A for MC1-D-183 to MC1-D323,32A for MC1-D183 connected with 2× 4mm 2 cable in parallel,40A for MC1-D253 and MC1-D323 connected with 2×4 mm 2  cables in parallel.
(2) The closing time "C" is measured from the moment the coil supply is swithed on to initial contact of the main poles.The opening time"O" is measured from the moment the coil supply is switched off to the moment the main poles separate.

Pole characteristics

Type of contactor

MC1-D-

D40

D50

D65

D80

D95

Rated operational current(te)
(Ue=440V)

In AC-3,?=60?

A

40

50

65

80

95

In AC-1,?=60?

A

60

80

80

125

125

Rated operational voltage(Ue)

Up to

V

1000

1000

1000

1000

1000

Frequency limits

Of the operating current

Hz

25...400

25...400

25...400

25...400

25...400

Conventional thermal current(1th)

?=60?

A

60

80

80

125

125

Rated making capacity(440V)

Conforming to IEC 947

 

800

900

1000

1100

1100

Rated breaking capacity(440V)

Conforming to IEC 947

 

800

900

1000

1100

1100

Permissible short-time rating
No current flowing for preceding
15 minutes at ?=40?

For 1 s

A

720

810

900

990

1100

For 10 s

A

320

400

520

640

800

For 1min

A

165

208

260

320

400

For 10 min

A

72

84

110

135

135

Protection by fuse against
short-circuits(U=690V)

Without thermal type 1

A

80

100

160

200

200

Overload relay,fuse gG type 1

A

80

100

125

160

160

With thermal overload relay

A

See pages 245 14/2 and 245 14/3,for aM or gG fuse ratings corresponding to the associated thermal overload relay

Average impedance per pole

At 1th and 50Hz

mO

1.5

1.5

1

0.8

0.8

0.6Power dissipation per pole for

AC-3

W

2.4

3.7

4.2

5.1

7.2

13.5The above operating currents

AC-1

W

5.4

9.6

6.4

12.5

12.5

a.c.control circuit characteristics

Rated control circuit voltage(Uc)

50/60Hz

V

24...660

20...500

Control voltage limits

50 or 60 Hz coils

Operational

 

0.85...1.1Uca t 55 ?

0.85...1.1Uca t 55 ?

50/60 Hz coils

Drop-out

 

0.3...0.6Uc at 55?

0.3...0.5Uca t 55 ?

 

Operational

VA

0.8...1.1 Uc on 50 Hz and 0.85...1.1 Uc on 60 Hz at 55?

0.8...1.1 Uc on 50/60 Hz at 55 ?

Drop-out

 

0.3...0.6 Uc at 55 ?

0.3...0.6 Uc at 55 ?

Average consumption
at 20? and at Uc

~50Hz

Inrush

50 Hz coil

VA

200

300

-

Cosf

 

0.75

0.8

0.9

50/60 Hz coil

VA

245

280...350

280...350

Sealed

50 Hz coil

VA

20

22

-

Cosf

 

0.3

0.3

0.9

50/60 Hz coil

VA

26

2...18

2...18

~60Hz

Inrush

50 Hz coil

VA

220

300

-

Cosf

 

0.75

0.8

0.9

50/60 Hz coil

VA

245

280...350

280-350

Sealed

 

VA

22

22

-

Cosf

 

0.3

0.3

0.9

50/60 Hz coil

VA

26

2...18

2...18

Heat dissipation 50/60 Hz

 

W

6...10

3...8

3...4.5

Operating time(2)

Closing "C"

ms

20...26

20...26

20...26

20...35

20...35

20...50

20...35

Opening "O"

ms

8...12

8...12

8...12

6...20

6...20

6...20

40...75

Mechanical life
in millions of operating cycles

50 or 60 Hz coil

 

16

16

16

10

10

8

-

50/60 Hz coil on 50 Hz

 

6

6

6

4

4

8

8

Maximum operating rate
at ambient temperature =60?

In operating cycles per hour

 

3600

3600

3600

3600

3600

2400

1200

(1) Versions with spring terminal connections:20A for MC1-D-093 and MC1-D-123,25A forMC1-D-183 to MC1-D-323,32A for MC1-D-183 connected with 2× 4mm2 cable in parallel,40A for MC1-D-253 and MC1-D-323 connected with 2×4mm2 cables in parallel.

 

Pole characteristics

Type

MC1-D09...38,T20...T40

MC1-D-40...65

MC1-D

MC1-D115&
MC1-D-150

Rated control circuit voltage(Uc) (V)

12...440

12...440

12...440

24...440

Rated insulation voltage(Conforming to IEC 947-1) (V)

690

690<, /P>

690

69.

Control voltage limits

Operatipnal

Standard coil

0.7..1.25Uc
at 60?

0.85...1.1Uc
at 55 ?

0.85...1.1Uc
at 55 ?

0.75...1.2Uc
at 55 ?

Wide range coil

--

0.75...1.2Uc
at 55?

0.75...1.2Uc
at 55?

--

Drop-out

 

0.1...0.25 Uc
at 60 ?

0.1...0.3Uc
at 55?

0.1...0.3Uc
at 55?

0.15...0.4Uc
at 55?

Average consumption at 20? and at Uc (W)

=

Inrush

5.4

22

22

270 to 365

Sealed

5.4

22

22

2.4...5.1

Average operating time (1) at Uc (ms)

Closing ("C")

55

85...110

95...130

20...35

Opening ("O")

20

20...35

20...35

40...75

Note:the arcing time depends on the circuit switched by the poles. For normal 3-phase applications ,the arcing time is ususlly less than 10ms .the load is isolated form the supply after a time equal to the sum of the opening time and the arcing time

Time constant(L/R) (ms)

28

65

75

25

Mechanical life Uc

In millions of operation cycles

30

20

20

8

Meximum operating rate at ambient temperature =60?

In operating cycles per hour

3600

3600

3600

3600

Low consumption control circuit characteristics

Rated insulation voltage

Conforming to IEC 947-1

V

690

--

--

--

Maximun voltage

Of the control circuit on =

 

250

--

--

--

Average consumption
d.c.at 20? and at Uc

Wide range coil(0.7...1.25Uc)

inrush

W

2.4

--

--

--

Sealed

W

2.4

--

--

--

Operating time (1) at Uc and at 20?

Closing

"C"

ms

70

--

--

--

opening

"O"

ms

25

--

--

--

Voltage limits (?=60?) of the control circuit

Operational

 

0.7 to 1.25 Uc

--

--

--

Drop-out

 

0.1...0.3 Uc

--

--

--

Time constant(L/R)

ms

40

--

--

--

Mechanical life

In millions of operating cycles

 

30

--

-

--

Maximum operating

At ambient temperature=60?

ops/h

3600

--

--

--

(1) Opening times depend on the type of contactor electromagent and its control mode .the closing time "C" is measured from the moment the coil supply is switched on to initial contact the main poles,the opening time "O" is measurd from the moment the coil supply is switched off to the moment the main poles separate.

Linked contacts conforming to draft standard IEC 947-4-5

Each contactor has 2 N/O and N/C contacts mechanically linked on the same movable contact holder

Mirror contact

The N/C contact on each contactor represents the state of the power contacts and can be connected to a PREVENTA safely module

Rated operational voltage(Uc)

Up to

V

690

Rated insulation voltage (Ui)

Conforming to IEC 947-1

V

690

Conventional thermal current(lth)

For ambient emperature =60?

A

10

Operating current frequency

 

Hz

25...400

Minimum switching capacity

U min.

V

17

?=10-8

I min.

mA

5

Short-circuit protection

Conforming to IEC 947-5-1

 

gG fuse:10A

Rated making capacity

Conforming to IEC 947-5-1.1rms

A

~:140, :250

Short-time rating

Permissible for

1 s

A

100

500ms

A

120

100ms

A

140

Insulation resistance

 

MO

>10

Non-overlap time

Guaranteed between N/C and N/O contacts

ms

1.5 on energisation and on de-energisation

 

Contact operating power
conforming to IEC 947-5-1

a.c. supply categories
AC-14 and AC-15
Electrical life (valid for up to 3600 operating cycles /hour)
On an inductive load such as the coil of an electromagnet:making power (cosf0.7) =10 times the power broken ((cosf0.4)

d.c.supply category DC-13
Electrical life (valid for up to 1200 operating cycles /hour)
on an inductive load such as the coil of an electromagnet ,without economy resistor,the time constant increasing increasing with the load.

1 million operating cycles

3 million operating cycles

10 million operating cycles

V

24

48

115

230

400

440

600

VA

60

120

280

560

960

1050

1440

VA

15

32

80

160

280

300

420

VA

4

8

20

40

70

80

100

V

24

48

125

250

440

W

96

76

76

76

44

W

48

38

38

32

--

W

14

12

12

--

--

 

 

 


Pre:CJX7 series contactors


Next:MC2-388 thru MC2-396 1/2 pole contactors( 30A thru 40A)

David Chang
Managing Director
Morning Sun Electric Co.,Ltd
Add:No.358,Liujiang rd,,liushi town,yueqing city,zhejiang province,China
Tel:0086-577-61586783
Fax:0086-577-61586785
MSN:morsun18@hotmail.com
GMAIL:morsun818@gmail.com
SKYPE:morsun818
Yhaoo messenger:morsun818@yahoo.com.cn