CJX2-D 115-620 AC Contactors

|

|

|

|
CJX2D 115 |
CJX2D 150 |
CJX2D 170 |
CJX2D 205 |
Contactor CJX2D |
|
115 |
150 |
170 |
205 |
245 |
300 |
410 |
475 |
620 |
Number of poles |
A |
3 |
3 |
3 |
3 4 |
3 4 |
3 4 |
2 3 4 |
2 3 4 |
2 3 4 |
Rated current (le)AC3 ue= 440V |
A |
115 |
150 |
170 |
205 |
245 |
300 |
410 |
475 |
620 |
Rated working voltage(Ue)max |
V |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
Rated insutating voltage(Ui) |
V |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
Rated impact withstand voltage(Uimp) |
KV |
8 |
8 |
8 |
8 |
8 |
8 |
8 |
8 |
8 |
Range of working current frequency |
Hz |
25-400 |
25-400 |
25-400 |
16-200 |
16-200 |
16-200 |
16-200 |
16-200 |
16-200 |
Short-circuit protective fuse |
?type combination |
A |
200 |
250 |
250 |
315 |
315 |
500 |
630 |
800 |
1000 |
?type combination |
A |
125 |
160 |
180 |
200 |
250 |
400 |
400 |
500 |
630 |
Machincial life |
106times |
8 |
8 |
8 |
10 |
10 |
10 |
10 |
10 |
5 |
Contactor CJX2D |
|
115 |
150 |
170 |
205 |
245 |
300 |
410 |
475 |
620 |
Short-circuit protective fuse |
Storage |
? |
-60...+80 |
Running |
? |
-5...+55 |
Permission |
? |
-40...+70 |
Max. altitude height of running |
M |
|
|
|
|
|
|
|
|
|
Way of installation |
|
The gradient between the installing surface and vertical surface not exceedihng ±30° |
Shock resistance 11 ms sine half-wave |
Contactor open |
g |
6 |
6 |
6 |
7 |
7 |
6 |
6 |
6 |
6 |
contactor closed |
g |
15 |
15 |
15 |
15 |
15 |
15 |
15 |
15 |
15 |
Vibration resistance 5 300Hz |
Contactor open |
g |
2 |
2 |
2 |
2 |
2 |
2 |
1.5 |
2 |
2 |
contactor closed |
|
4 |
4 |
4 |
5 |
5 |
5 |
5 |
4 |
4 |
Class of pollution |
|
Pollution class? |
Class of protection |
Main circuit |
|
Prevent the fingers from direct contacting |
Coil teminal |
|
Prevent the fingers from direct contacting |
Protective treatment |
|
TH |
Characteristics of control circuit |
Contactor CJX2D |
115 |
150 |
170 |
205 |
245 |
300 |
410 |
475 |
620 |
Rated control voltage |
|
|
V |
24-500 |
24-1000 |
42-1000 |
Action voltage |
Making |
50H,60Hz |
% |
0.85-1.1Uc |
50Hz/60Hz |
% |
0.85-1.5Uc |
0.85-1.5Uc |
0.85-1.1Uc |
Release |
50H,60Hz |
% |
0.3-0.5Uc |
50Hz/60Hz |
% |
0.2-0.65Uc |
Average power consumption |
Making |
50Hz |
VA |
300 |
- |
- |
805 |
805 |
- |
- |
- |
- |
60Hz |
VA |
360 |
- |
- |
970 |
970 |
- |
- |
- |
- |
50Hz/60Hz |
VA |
450 |
450 |
450 |
- |
- |
650 |
1075 |
1100 |
1650 |
Keep |
50Hz |
VA |
22 |
- |
- |
55 |
55 |
- |
- |
- |
- |
60Hz |
VA |
22 |
- |
- |
66 |
66 |
- |
- |
- |
- |
50Hz/60Hz |
VA |
6 |
6 |
6 |
- |
- |
10 |
15 |
18 |
22 |
Max.operating frequencym,Ambient temperature =55? |
time/h |
2400 |
1200 |
1200 |
2400 |
1200 |
1200 |
1200 |
1200 |
1200 |

|

|

|

|
CJX2D245 |
CJX2D300 |
CJX2D410 |
CJX2D475 |
Type |
Rated current AC3 Ue =440 CJX2D 115 |
Rated heating current AC10= 40° |
Rated power AC3 three - phase motor 0=40° |
Rated power AC4 three- phase motor 0<40 |
Weight |
Volume HXLXW |
220/ 240 V |
380/ 400 V |
400 V |
500 V |
600/ 690 V |
1000 V |
200/ 230 V |
380/ 400 V |
440 V |
500 V |
CJX2D 115 |
A |
A |
KW |
KW |
KW |
KW |
KW |
KW |
KW |
KW |
KW |
KW |
Kg |
mm3 |
CJX2D 150 |
115 |
200 |
30 |
55 |
59 |
75 |
80 |
75 |
9 |
18.5 |
18.5 |
30 |
2.25 |
158X120 X132 |
CJX2D 170 |
150 |
250 |
40 |
75 |
80 |
90 |
100 |
90 |
11 |
22 |
22 |
37 |
2.25 |
158X120 X132 |
CJX2D 205 |
170 |
250 |
55 |
90 |
100 |
110 |
110 |
100 |
12 |
40 |
45 |
51 |
2.25 |
158X120 X132 |
CJX2D 115 |
205 |
275 |
63 |
110 |
110 |
120 |
129 |
100 |
25 |
45 |
51 |
59 |
4.6 |
174X181 X168.5 |
CJX2D 245 |
245 |
315 |
75 |
132 |
132 |
160 |
160 |
147 |
30 |
55 |
63 |
75 |
4.7 |
197X181 X168.5 |
CJX2D 300 |
300 |
400 |
100 |
160 |
200 |
200 |
220 |
160 |
37 |
63 |
75 |
80 |
8.2 |
206X219 X213 |
CJX2D 410 |
410 |
500 |
110 |
220 |
250 |
250 |
280 |
185 |
40 |
75 |
80 |
90 |
8.5 |
206X219 X213 |
CJX2D 475 |
475 |
700 |
147 |
265 |
280 |
335 |
355 |
335 |
45 |
80 |
100 |
110 |
10.8 |
238X233 X232 |
CJX2D 620 |
620 |
1000 |
200 |
335 |
400 |
400 |
450 |
450 |
55 |
100 |
110 |
132 |
17.4 |
304X255 X309 |
Auxiliary contactor block(Recommend to use):
|
Auxiliary instantaneous contactor block,contactor? LA1-DN10C LA1-DN01C

|
|
Auxiliary instantaneous contactor block, contactor ? LA1-DN11C LA1-DN20C LA1-DN02C

|
|
Auxiliary instantaneous contactor block, contactor ? LA1-DN40C LA1-DN31C LA1-DN22C LA1-DN13C LA1-DN04C

|
|
Time delay auxiliary contactor block making and delay S 0.1...3S LA2-DT0 0.1...30S LA2-DT2 10...180S LA2-DT4 1...30S LA2-DS

|
|
Tme delay auxiliary contactor block releasing and delay S 0.1...3S LA3-DR0 0.1...30S LA3-DR2 10...180S LA3-DR4

|
|
Accessoriesl:

|
Side-mounted auxiliary module LA8-DN11C LA8-DN20C Add 2 instantaneous contact sets extra not increase the height of cabinet other modules can be added on the frontal of contactor and controlling relay applicable for the contactor and controlling relay below D170 |

|
Mechanical interlocking module Its design is rather ingenious and contains 2 NC contact sets which can be used as mechanical and electric interlock, so it is unnecessary to add other interlocks extra applicable for the contactor and controlling relay below D170 |

|
LA9-D..02 09 equiped with LC1-D09~D38 LC1-D06N~D25N 40 equipped with LC1-D40~D95 115 equipped with LC1-D115~D170 |
Pre:LC1-F AC Contactors
Next:LA1-D Contact block
David Chang
Managing Director
Morning Sun Electric Co.,Ltd
Add:No.358,Liujiang rd,,liushi town,yueqing city,zhejiang province,China
Tel:0086-577-61586783
Fax:0086-577-61586785
MSN:morsun18@hotmail.com
GMAIL:morsun818@gmail.com
SKYPE:morsun818
Yhaoo messenger:morsun818@yahoo.com.cn